High Temperature Fan Manufacturer and Industrial Thermal Process Fans

 

 

Designed for continuous operation in extreme thermal environments, our high temperature fans convey hot air, flue gas, and process vapors at temperatures ranging from +150 deg C to +1,000 deg C. Each unit integrates high-temp alloy impellers, thermal expansion housings, and specialized shaft cooling discs or water-cooled bearing pedestals to prevent heat conduction into drive components. Available in centrifugal, axial, and duct-insertion designs compliant with AMCA 210 and ISO 5801 performance standards.

 

 
  • Mixed-flow High-temperature Exhaust Fan
    In the high-temperature exhaust systems of industrial kilns, the hot air extraction of drying equipment, and the high-temperature gas discharge of chemical processes, operating conditions often require both certain pressure to overcome...
    view more
  • High-temperature Ducted Axial Fan
    In the exhaust systems of industrial furnaces, the hot air conveyance pipelines of drying equipment, and the high-temperature gas ducts of chemical processes, fans are often required to be directly connected in series in the duct to...
    view more
  • High-temperature Axial Flow Ventilator
    In the baking workshops of food factories, the drying sections of coating production lines, and the aging rooms of wood processing plants, what is needed is not only to extract high-temperature air but also to maintain a certain airflow...
    view more
  • Industrial Mixed-flow High-temperature Fan
    In hot air circulation for heat treatment furnaces, hot air conveyance for drying lines, and gas turbine inlet air preheating systems, operating conditions often fall between pure axial and pure centrifugal — temperatures of 200–400°C,...
    view more
  • Industrial Heat-resistant Centrifugal Fan
    Some industrial processes are not intermittently high-temperature but continuously convey high-temperature gas 24/7, 365 days a year — such as kiln tail induced draft fans in cement plants and boiler induced draft fans in power plants....
    view more
  • High-temperature Axial Flow Fan
    On the air-cooled islands of large thermal power plants, beside annular coolers in metallurgical enterprises, atop cooling towers in chemical plants — what is needed is not high-pressure gas conveyance but pushing large volumes of...
    view more
  • Industrial High-temperature Centrifugal Fan
    In industrial processes such as cement rotary kilns, metallurgical blast furnaces, and chemical cracking furnaces, fans need to convey not room-temperature air but high-temperature gases of 250°C or even 500°C+. Ordinary fans at such...
    view more
  • Centrifugal High Temperature Fan
    The Centrifugal high temperature fan is engineered as a heavy-duty centrifugal machine specifically for conveying hot gases ranging from 250°C to over 500°C. It effectively addresses critical challenges such as material strength...
    view more
  • Axial Flow High Temperature Fan
    The Axial flow high temperature fan is expertly engineered for high-volume gas movement along the axis in demanding thermal environments. Its hallmark is a compact, direct-flow design that delivers superior efficiency, making it the...
    view more
  • High Temp Duct Fan
    The High Temp Duct Fan (Mixed-Flow) is an excellent choice for moving process air in medium-temperature, medium-resistance systems. It effectively bridges the gap between purely axial and purely centrifugal designs, making it highly...
    view more
  • Mixed-flow High-temperature Fan
    The Mixed-Flow High-Temperature Fan (Angled Discharge) is a specialized mixed-flow fan featuring a discharge outlet angled at 45° or 60° from the axis. This innovative design allows for exceptionally compact integration directly into...
    view more
  • Volute High-pressure High-temperature Fan
    The Volute High-Pressure High-Temperature Fan is engineered as a robust workhorse capable of withstanding the dual challenges of extreme pressure (total pressure >15 kPa) and intense heat (>300°C). This rugged centrifugal fan is the...
    view more
First 12 Last
 
Fan Selection and Configuration Guide

 

Fan Type

Max. Operating Temperature

Airflow Range

Pressure Range

Primary Industrial Application

Centrifugal High Temp Fan

Up to +800 °C

1,500 - 350,000 m3/h

500 - 15,000 Pa

Industrial kiln hot air recirculation, boiler induced draft, and flue gas exhaust

Axial Flow High Temp Fan

Up to +500 °C

3,000 - 180,000 m3/h

100 - 800 Pa

High-volume thermal circulation in baking ovens, drying tunnels, and aging rooms

Mixed-Flow High Temp Fan

Up to +400 °C

2,500 - 90,000 m3/h

300 - 2,500 Pa

In-line ducted process ventilation where space constraints prevent 90-degree centrifugal duct turns

Insertion / Plug High Temp Fan

Up to +1,000 °C

1,000 - 60,000 m3/h

200 - 3,500 Pa

Direct mounting into furnace walls or insulated oven plenums without external casing heat losses

 

Materials and High-Temp Construction Options

 

High-temperature Axial Flow Fan

Impeller and Shaft Materials

Grade 304 stainless steel (up to 400 deg C), Grade 316L (up to 500 deg C), Grade 310S / 2520 high-nickel alloy (up to 900 deg C), and Inconel 625 or Hastelloy C-276 for continuous operating zones exceeding 900 deg C or aggressive chemical combustion environments.

 
High-temperature Ducted Axial Fan

Thermal Isolation and Cooling Options

Cast aluminum heat-dissipating cooling discs mounted on the drive shaft, forced-air cooling jackets, or water-cooled bearing housings for severe continuous thermal loads.

 
Industrial High-temperature Centrifugal Fan

Insulated Fan Housings

Double-wall insulated casings pre-filled with high-density ceramic fiber insulation (50 mm to 150 mm thickness) to minimize skin temperature and radiant heat loss.

 
Industrial Mixed-flow High-temperature Fan

High-Temperature Shaft Seals

Multi-layer stuffed PTFE, ceramic fiber gland packing, labyrinth mechanical seals, or purge-gas pressurized shaft seals to prevent flue gas leakage.

 

 

Technical Specifications and Performance Limits

 

Parameter

Technical Specifications

Impeller Diameter

280 mm to 2,200 mm

Drive Arrangements

Arrangement 1: Overhung impeller, belt drive; Arrangement 4: Direct drive with insulated shaft extension; Arrangement 8: Direct drive via flexible coupling on structural pedestal; Arrangement 9: Belt drive with motor mounted on bearing frame

Motor Protection & Efficiency

TEFC enclosure; Class H insulation; IP55 / IP65 protection; standard IE3 / IE4 motors mounted outside the airstream; VFD-compatible winding protection

Bearings & Lubrication

Heavy-duty pillow block bearings, SKF or NSK; high-temperature synthetic grease or oil-bath lubrication with internal cooling coils

Bearing Life

L10 >= 40,000 hours

Dynamic Balancing

Two-plane dynamic balancing at operating speed; ISO 1940 Grade G2.5

Vibration Limit

RMS vibration velocity <= 1.8 mm/s at bearing housings under full thermal equilibrium, according to ISO 10816-3 Category I/II guidelines

Thermal & Structural Design

Structural expansion joints integrated to minimize housing distortion during thermal expansion

 

 
 
Applications by Industry
01.

Heat Treatment and Metallurgical Processing

Recirculating protective atmosphere gases inside annealing furnaces, tempering ovens, and aluminum homogenizing furnaces.

02.

Ceramics, Glass and Brick Kilns

Kiln tail induced draft exhaust, waste heat recovery conveyance, and rapid cooling zone air injection.

03.

Industrial Drying and Food Processing

Continuous hot air delivery in conveyor dryers, spray drying towers, and rotary drum dryers.

04.

Chemical and Waste Incineration

Extracting hot corrosive flue gases and volatile organic compound (VOC) thermal oxidizer exhaust.

 

Custom Fan Engineering and Retrofit Capabilities

 

Industrial Mixed Flow Fan

Cold-Start Damper and VFD Interlocks

Integration of automated inlet dampers or VFD speed controls to prevent motor overload during initial ambient cold starts.

Mixed-flow High-temperature Exhaust Fan

Thermal Stress and Creep Analysis

Finite Element Analysis (FEA) performed on high-temp impellers to verify yield strength and creep deflection under maximum centrifugal force at peak temperatures.

Medium-pressure High-temperature Fan

Custom Flange and Mounting Footprints

Matching existing duct connection flanges and structural steel foundations during plant retrofits and fan replacements.

 

Manufacturing Precision and Quality Assurance
 
 
 

CNC Laser Cutting and Structural Welding

Housing plates and impeller blades precision-cut within +/-0.05 mm. AWS D1.1 and EN 287-1 certified welders execute full-penetration welds on high-alloy assemblies.

 
 

Non-Destructive Testing (NDT)

100% dye penetrant testing (PT) on all high-stress impeller welds. Ultrasonic testing (UT) or X-ray inspection applied to critical shaft and hub joints upon request.

 
 

High-Speed Dynamic Balancing

Impellers undergo dynamic balancing on computerized balancing machines, compensating for keyways and shaft lock-assemblies according to ISO 1940 G2.5 guidelines.

 
 

Factory Acceptance Testing (FAT)

Every fan completes a 60-minute continuous run test checking vibration spectra, bearing temperature rise, motor current draw, and shaft alignment before shipment.

 

 

Export Packaging and Project Documentation
 

Ocean Cargo Packaging

Heavy-duty ISPM-15 compliant fumigated wooden crates or steel skid frames. Critical shaft ends, bearing housings, and machined flange faces treated with anti-corrosion grease and sealed in waterproof vapor-barrier film.

Engineering Documentation Package

Every shipment includes General Arrangement (GA) 2D/3D CAD drawings, material test reports (MTR to EN 10204 3.1), dynamic balance certificates, FAT inspection reports, and maintenance instructions.

 

 

FAQ

 

Q: How do you protect bearings from overheating on high temperature fans?

A: Bearings are isolated outside the hot airstream on a dedicated structural pedestal. A cast-aluminum cooling heat-sink disc is installed on the shaft between the fan housing and the inner bearing to radiate heat into the ambient air. For process temperatures exceeding 500 deg C, water-cooled bearing housings or oil-bath lubrication systems are used.

Q: Why does motor power requirement change between cold startup and hot operating temperature?

A: Gas density is higher at room temperature than at elevated operating temperatures. Running a high-temperature fan at full speed when the process gas is cold requires significantly more shaft horsepower, which can trip the motor breaker. We account for this by specifying cold-start inlet dampers or programming VFD acceleration ramps.

Q: How do you select the correct alloy for different temperature zones?

A: Material selection is determined by yield strength at temperature and resistance to thermal creep or oxidation. We specify Stainless Steel 304 up to 400 deg C, Stainless Steel 316L up to 500 deg C, Stainless Steel 310S up to 900 deg C, and nickel-base alloys like Inconel 625 for environments approaching 1,000 deg C or containing corrosive flue combustion gases.

Q: What design features prevent thermal stress deformation in the fan housing?

A: Housings incorporate sliding support feet and oversized bolt clearance slots to accommodate 3-dimensional thermal expansion without buckling weldments. Thermal expansion joints (flexible metallic or fabric bellows) are recommended at both inlet and outlet duct connections.

Q: What technical parameters are required to receive a fan selection calculation?

A: Provide operating gas temperature (deg C), required airflow capacity (m3/h or CFM), total or static pressure (Pa), gas composition (air, flue gas, dust concentration), site altitude, power supply (V/Hz), and cold startup ambient conditions.

Q: What is the standard lead time for custom high temperature process fans?

A: Standard stainless steel models (304 / 316L) typically ship within 20 to 25 business days. Heavy-duty units requiring high-nickel alloys (310S, Inconel), water-cooled bearing systems, or special NDT testing ship within 30 to 40 business days following drawing approval.

 

modular-1
Request a Fan Selection and Engineering Quotation

Need an engineering review, CAD model, or custom quotation for your ventilation project? Provide your operating requirements to our engineering sales office:
E-mail: nyfji@126.com

Direct Phone / WhatsApp: +86 186 6290 3785

Factory Address: North End of Jiuwei Port Bridge, Nantong City, Jiangsu Province, China

Included with Quotation: Airflow Performance Curves, Dimensioned CAD Drawings, Motor Data Sheets, and Itemized FOB/CIF Commercial Terms within 24 hours.

As one of the leading high temperature fan manufacturers and suppliers in China, we also support customized service with low price. Please feel free to buy discount high temperature fan made in China here from our factory. For quotation, contact us now.

Axial Flow High Temperature Fan, Centrifugal High Temperature Fan, Mixed flow High temperature Fan
Send Inquiry