Industrial Ventilation Fans Manufacturer

 

 

Nantong Nanyang Fan Manufacturing Co., Ltd. manufactures axial, roof supply/exhaust, inline duct, and heavy-duty wall-mounted ventilation fans for factory workshops, warehouses, commercial buildings, and agricultural facilities. Produced under ISO 9001 quality management, our ventilation units provide measurable air exchange rates, pressure characteristics, and noise compliance for HVAC contractors, OEM partners, and industrial facility administrators.

 

 
  • Industrial Mixed Flow Fan
    Walk into the production workshop of a cement plant, steel mill, or chemical factory, and the ventilation equipment faces not clean air but a harsh medium — high temperature, high dust, and corrosive gases. Ordinary mixed flow fans in...
    view more
  • Axial Flow Fan
    From heat dissipation in factory workshops to ventilation in agricultural greenhouses, from air circulation in underground parking lots to rapid extraction of kitchen fumes, the axial flow fan — with its simple structure, high airflow,...
    view more
  • Mixed Flow Fan
    In scenarios with moderate requirements for both airflow and pressure, combined with sensitivity to operating noise and energy consumption — such as commercial building HVAC ventilation, underground parking smoke extraction, and...
    view more
  • Horizontal Axial Flow Compressor
    In heavy industrial scenarios requiring continuous, stable supply of high-flow compressed air — such as large-scale thermal power generation, steel smelting, and cement production — a Horizontal axial flow compressor with convenient...
    view more
  • Vertical Axial Flow Compressor
    In industrial processes requiring high-flow, medium-to-high pressure gas delivery — such as chemical synthesis, metallurgical blast air supply, and wastewater treatment aeration — a compact, stably operating Vertical axial flow...
    view more
  • Heavy Duty Axial Fan
    In scenarios with near-critical ventilation reliability requirements — such as underground mines, tunnel construction, and power plant buildings — a heavy duty axial fan capable of delivering sustained, stable high airflow often...
    view more
  • Industrial Axial Flow Fan
    Industrial Axial Flow Fans are engineered to deliver high-volume airflow at low to medium pressure, making them the preferred choice for straight-through ventilation systems. These fans move air parallel to the shaft axis, providing...
    view more
  • Axial Flow Type Compressor
    The Axial Flow Type Compressor represents a pinnacle of turbomachinery, engineered for the most demanding industrial applications that require immense gas volumes and a medium pressure rise. Operating on principles similar to those of...
    view more
  • Vertical Mixed Flow Fan
    The Vertical Mixed Flow Fan is a specialized unit designed for vertical or shaft ducting, skillfully combining the high-pressure capability of centrifugal fans with the high-volume airflow of axial fans. Air enters axially and is...
    view more
  • Horizontal Mixed Flow Fan
    The Horizontal Mixed Flow Fan is the ideal solution for long-distance horizontal air distribution where maintaining pressure is challenging. This innovative design combines the advantages of both axial and centrifugal fans: it connects...
    view more
 
Fan Selection

 

Fan Category / Configuration

Airflow Range (m3/h)

Static Pressure (Pa)

Impeller / Housing Material

Primary Application Scenario

Drive / Motor Protection

Wall-Mounted Axial Fan

2,000 - 85,000

50 - 250

Cast Aluminum / Galvanized Steel

High-volume wall exhaust for factories, warehouses, and greenhouses.

Direct Drive / IP55, Class F

Inline Circular/Rectangular Duct Fan

300 - 15,000

150 - 900

Galvanized Sheet Steel / Plastic

Ducted supply/exhaust for commercial offices, restrooms, and indoor venues.

Direct Drive / Sealed Bearing

Roof Ventilator (Supply / Exhaust)

1,500 - 110,000

100 - 650

FRP / Aluminum / Stainless Steel

Roof-top heat and fume extraction, general building pressure balancing.

Direct or Belt Drive / IP55

Portable / Vane Axial Blower

1,200 - 25,000

200 - 1,200

Powder-Coated Carbon Steel

Confined space ventilation, tunnel air supply, temporary spot cooling.

Direct Drive / IP54 or Ex d

Corrosion / Explosion-Proof Fan

1,000 - 60,000

80 - 500

FRP / Stainless Steel 316L / Brass Trim

Chemical storage, battery rooms, hazardous gas exhaust, high-humidity zones.

Direct Drive / ATEX Ex d IIBT4

 

Materials & Construction Options

 

Housing & Structural Framing
Galvanized Steel Sheet: Zinc coating weights from 180 g/m2 to 275 g/m2 for rust protection in indoor and commercial applications.

 

Fiberglass Reinforced Plastic (FRP): Corrosion-resistant resin formulations for wet chemical fumes, coastal salt-air, and composting facilities.

 

Stainless Steel (304 / 316L): Passivated metal construction for food processing, pharmaceutical cleanrooms, and washdown environments.

 

Structural Frame: Heavy-gage rolled steel flanges with pre-punched mounting holes for direct attachment to wall sleeves or ductwork.

 

Impeller & Blade Design
Die-Cast Aluminum Blades: Aerodynamically profiled airfoil blades with adjustable pitch angles to calibrate airflow and power draw.

 

UV-Stabilized Polypropylene (PAG): Lightweight composite blades for reduced startup torque, low noise generation, and chemical resistance.

 

Stainless Steel / Pressed Steel Blades: Stamped and statically balanced for harsh thermal or industrial exhaust applications.

Axial Flow Fan

 

Technical Specifications

 

Parameter

Standard Range / Specification

Airflow Volume

300 m3/h to 110,000 m3/h (175 CFM to 64,700 CFM)

Static Pressure Range

30 Pa to 1,200 Pa (0.12 in. wg to 4.8 in. wg)

Operating Temperature

-20 Deg C to +60 Deg C (Standard) / Up to +120 Deg C (Special high-temp insulation)

Impeller Diameter

200 mm to 1,600 mm (8 in. to 63 in.)

Noise Level Output

45 dB(A) to 82 dB(A) at 3 meters (dependent on size, RPM, and silencing accessories)

Supply Voltage Options

110V / 220V / 380V / 415V / 460V, 50 Hz / 60 Hz (Single or Three-Phase)

Motor Efficiency Rating

IE2 High Efficiency / IE3 Premium Efficiency compliant with IEC standards

Airflow Testing Standard

Aerodynamic performance tested in accordance with ISO 5801 and AMCA 210 testing protocols

 

Applications by Industry

 

Industrial Manufacturing Workshops

Heat dissipation, oil mist extraction, and continuous air turnover in welding, molding, and machining halls.

01

Warehouses & Logistics Hubs

Moisture control, elimination of thermal stratification, and air circulation in high-bay storage areas.

02

Agricultural & Livestock Facilities

Temperature regulation and ammonia gas exhaust in poultry houses, dairy barns, and commercial greenhouses.

03

Commercial Facilities & Underground Parking

CO gas extraction, general duct exhaust, and stairwell pressurization systems.

04

Chemical & Battery Storage Facilities

Constant dilution and extraction of volatile organic compounds (VOCs) and corrosive vapors.

05

 

Custom Fan Engineering & OEM Capabilities
 

Aerodynamic & Structural Modification

Custom blade pitch adjustment to hit specific duty points (CFM at designated static pressure) without changing frame size.
Dimensional matching for existing wall sleeves, roof curbs, or duct connections to replace legacy ventilation units.

OEM Branding & Packaging Setup

Custom motor nameplates, warning labels, and wiring diagrams in multi-language layouts.
Tailored housing colors (powder coating to RAL specifications) and private label silk-screening.

 

 

 

Manufacturing & Quality Control

 

Our ventilation fan production line incorporates automated punching, blade balancing, protective coating, and 100% electrical safety verification.
Sheet Metal Laser Cutting & Stamping
Blade Casting / Pressing & Dynamic Balance Calibration
Surface Pre-treatment & Epoxy Powder Coating
Motor Assembly & Wiring Integration
Run Test (Vibration, Noise, Current Draw, Hi-Pot)
Final Inspection & Protective Packaging

 

Blade & Wheel Balance: Impellers undergo dynamic balancing according to ISO 1940 Grade G6.3 / G2.5 to eliminate shaft vibration and extend bearing operational life.

 

Electrical Safety Verification: Every assembled fan undergoes dielectric voltage withstand (Hi-Pot) testing, insulation resistance checks, and ground continuity testing before packing.

 

Acoustic & Airflow Audit: Random batch samples undergo sound level measurements (dB(A)) and pressure-airflow curve verification in our air chamber setup.

Mixed Flow Fan

 

Packaging & Project Support

 

Stackable / Knock-Down (KD) Packaging: Select axial wall fans and roof units ship in knock-down formats to optimize sea container loading capacity and lower freight expenses.

 

Protection Standards: Heavy-duty corrugated cartons with internal molded foam cradles or ISPM 15 compliant heat-treated wooden crates for large industrial units.

 

Documentation Included:
Dimensioned 2D CAD Outline Drawings and 3D Models (STEP format).
Airflow Performance Curves (Pressure vs. Volume vs. Power).
Electrical Wiring Schematics and CE Compliance Declarations.
Installation and Maintenance Instruction Manuals.

Industrial Mixed Flow Fan

 

 

FAQ

 

Q: How do you ensure your fans operate reliably in high-humidity or outdoor environments?

A: Outdoor and roof-mounted fans feature IP55-rated sealed motors, drain holes in housing low points, stainless steel hardware, and UV-resistant powder coating or FRP construction to prevent moisture damage and rust formation.

Q: What options are available to reduce fan operating noise?

A: Noise reduction options include selecting multi-pole slower-speed motors (960 RPM / 1440 RPM), specifying backward-curved or airfoil blade geometry, adding inlet/outlet silencers, and installing rubber vibration isolators during mounting.

Q: Can your ventilation fans be integrated with variable frequency drives (VFD)?

A: Yes. Our three-phase motors can be specified with VFD-compatible phase insulation and insulated bearings to allow speed control from 20 Hz to 60 Hz without electrical damage to motor windings.

Q: What certification standards do your ventilation fans meet for international export?

A: Our standard ventilation fans comply with CE directives for machinery and electrical safety (LVD/EMC). Explosion-proof variants meet ATEX requirements, and motors conform to IEC high-efficiency standards (IE2/IE3).

Q: What is the typical lead time for OEM or custom-branded fan orders?

A: Standard catalog models ship within 15 to 20 days. Custom motor voltages, special color powder coatings, or OEM private-label production runs typically carry a manufacturing lead time of 25 to 30 days.

 

modular-1
Request a Fan Selection & Commercial Quotation

Need an engineering review, CAD model, or custom quotation for your ventilation project? Provide your operating requirements to our engineering sales office:
E-mail: nyfji@126.com

Direct Phone / WhatsApp: +86 186 6290 3785

Factory Address: North End of Jiuwei Port Bridge, Nantong City, Jiangsu Province, China

Included with Quotation: Airflow Performance Curves, Dimensioned CAD Drawings, Motor Data Sheets, and Itemized FOB/CIF Commercial Terms within 24 hours.

As one of the leading ventilation fan manufacturers and suppliers in China, we also support customized service with low price. Please feel free to buy discount ventilation fan made in China here from our factory. For quotation, contact us now.

Vertical Mixed Flow Fan, ventilation fan, Industrial Axial Flow Fan
Send Inquiry